- Chargers[3]
- Circuit Breakers[4]
- Insulation Materials & Elements[10]
- Event & Party Supplies[2]
- LED Bulbs & Tubes[10]
- Industrial Lighting[10]
- LED Flashlights[3]
- LED Headlamps[3]
- LED Lamps[10]
- Other LED Lighting[1]
- Floodlights[10]
- Garden Lights[1]
- Lawn Lamps[7]
- Outdoor Wall Lamps[3]
- Street Lights[10]
- Underground Lamps[4]
- Underwater Lights[10]
- Flashlights & Torches[7]
- Ceiling Lights[6]
- Downlights[10]
- Grille Lamps[6]
- Wall Lamps[1]
- Composite Pipes[1]
- HDPE[2]
- Other Police & Military Supplies[1]
Outdoor High-voltage Vacuum Circuit Breaker
Product Detailed
1. Vacuum Circuit Breaker
2. 200;400;630A
3. 12KV
4. Expeienced Manufacturer
5. Quick Delivery
1. > Commodity: High Voltage Vacuum Circuit Breaker
2. > Model No.: ZW6-12
3. > Specifications:
ZW6-12 Series Outdoor High Voltage Vacuum Circuit Breaker | ||
1.Application: Applicable to 3 phase electric system, functioning as opening/closing load current, overload current and short circuit current. | ||
2. Operating Environment | ||
1> Ambient Temperature | Max. +40°C | |
Min. -40°C | ||
2. Design Altitude above Sea Level | ≤1000m | |
3. Wind Pressure | ≤7000Pa | |
(Equivalent to 34m/s) | ||
4.Earth Quake Protection | ≤8 degree | |
5.Pollution Level | IV | |
6.Max.Diurnal Range of Temperature | ≤25°C | |
Main Parameters: | ||
1. Rated Voltage | KV | 12 |
2. Rated Insulation Level | KV | |
1min Power Frequency Withstand Voltage | DRY | 42 |
Wet | 34 | |
Rated Lighthing Withstand Current | 75 | |
3. Rated Current | A | 200;400;630 |
4. Rated Short Circuit Opening Current | KA | 12.5;16.2 |
5. Rated Operation Squence | O-0.3s-CO-3min-CO | |
6. Rated Short Circuit Opening Current | Times | 30 |
7. Rated Short Circuit Peak Closing Current | KA | 31.5;40;50 |
8. Rated Short Time Peak withstand Current | ||
9. Rated Short Time withstand Current | 12.5;16;20 | |
10.Rated Duration of Short Circuit | s | 4 |
11.Rated Opening Time | ms | ≤50 |
12.Rated Closing Time | ≤60 | |
13.Mechanical Life | Times | 10000 |
14.Closing Load | J | 70 |
15.Motor Power Consumption | W | ≤220 |
16.Rated Voltage and Aux.Transformer for Motor at A.C. Condition | V | DC220,110,24 |
AC220,110,24 | ||
17. Time Required for Motor to Charge the Spring | s | <14 |
18.Overload Current Trip Coil | ||
Rated Current | A | 5 |
Tripping Crrent Accuracy | % | ±10 |
Please feel free to ask us if you got any questions. Our engineer team can help buyer with some special requests. Many other models are available.